Con-Treat are specialists in cost effective, moisture barrier solutions
Moisture Fix 1
Finally there is a moisture barrier product formulated for the flooring installer/contractor that is an easy and simple to apply alternative to messy two part epoxy concrete moisture barrier systems. Moisture Fix is a single pack (no mixing) ready to use, easy pour, broom applied liquid moisture barrier. It deeply penetrates & forms a non-destructive colloidal gel which provides permanent concrete waterproofing / moisture barrier that withstands hydrostatic pressure.
Moisture Fix is highly cost effective, moisture barrier solution which has an extremely long shelf life and allows early access with minimum disruption. It is user friendly, non-toxic, non-flammable, zero VOC, environmentally safe and odourless. Available in 10 & 20 litre re-sealable pails.
TIMBER....BATTENED, MECHANICAL FIX OR FLOATING FLOORS
(NOT FOR DIRECT ADHESIVE OR GLUE FIX )
Moisture Fix 2 is designed specifically for Battened (mechanical fix) Overlay, Loose Laid, or Floating Timber Floors where there is no direct stick adhesive required. Moisture Fix 2 deeply penetrates and forms a non-destructive colloidal gel which provides a permanent concrete moisture barrier that withstands hydrostatic pressure. Moisture Fix 2 also has an amount of special polymer blend to enable eradication of the problems encountered with vapour condensation in the cavity between the concrete substrate and the underside of the timber. You can't apply too much of this product as all it does is leave an additional coating on top of the concrete that doesn't need to be removed as the battens are mechanically fixed and not glued.
Moisture Fix 2 is highly cost effective, has extremely long shelf life and allows early access with minimum disruption. This moisture barrier is user friendly, non-toxic, non-flammable, zero VOC, environmentally safe and odourless. Available in 10 & 20 litre re-sealable pails.
Simple Application, Highly Cost Effective, No Mess, Concrete Moisture Barrier!
Moisture Fix Demonstration
Note:
CRACKS are always a problem for the installer. So often the client is asking for the installer to take risks and responsibility for repairing cracks that should be referred to the engineer or builder for a recommended crack repair procedure that takes away the responsibility of possible failure from the installer. This is especially the case in regards to structural cracking where the void is full depth of the concrete. In this case, Moisture-Fix should be applied first before applying your normal crack repair system. In most cases, cracks are not full depth and are only micro or surface cracking, commonly caused by rapid surface drying or plastic shrinkage which would be not effect the efficiency or the result of Moisture-Fix. It is worth noting that Moisture-Fix is not designed or makes claim to fix cracks, however there are many applications where moisture has migrated through cracks of 1mm (even with hydrostatic pressure present) that have been eliminated permanently.